IP65 handles dust and water jets, IP67 adds short immersion to 1 meter, and IP68 covers deeper immersion that only the manufacturer can define.
One wrong assumption about a rating can put a monitor out of commission in a wet barn, wash bay, or outdoor kiosk. An IP code comes from IEC 60529; the first digit covers dust and solid objects, the second covers water. The letters describe what the enclosure survived in a lab, not a guarantee of a waterproof screen.
What Do The Three Ratings Actually Protect Against?
All three share a “6” in the first position — dust-tight, with no dust entering during the test. The second digit is where they diverge.
- IP65 — water jets from any direction. Good for hosing down, splashing, and washdown within the maker’s limits. Not rated for dunking.
- IP67 — temporary immersion, generally up to 1 meter for at least 30 minutes under the IEC test. Does not automatically include IP65’s jet protection.
- IP68 — immersion beyond IP67. Depth and duration are set by agreement between manufacturer and user, and the test must be more severe than IP67’s. “IP68” alone is an incomplete spec.
The most common mistake: assuming a higher number covers the lower one. It doesn’t — IP67 and IP68 monitors are not automatically jet-rated, because the water tests are different procedures. For both hosing and dunking, look for a combined mark such as IP65/IP67 or IP65/IP68.
Which Rating Fits Your Monitor Setup?
Match the rating to the water exposure you expect, not the highest number on the box. A hosed-down food-processing line needs jet protection; a dock-side display that might get swamped needs immersion ratings with published depth figures.
| Rating | Water Exposure Covered | Best Fit For |
|---|---|---|
| IP65 | Low-pressure water jets from any direction | Washdown bays, dusty workshops, splash zones |
| IP67 | Temporary immersion, generally 1 m for 30+ minutes | Docks, outdoor kiosks, occasional flooding |
| IP68 | Immersion beyond IP67, depth set by the maker | Submerged or near-submerged installations |
| IP65/IP67 | Jets plus temporary immersion | Washdown areas that also flood |
| IP65/IP68 | Jets plus deep immersion | Harsh marine and industrial sites |
| IP66 | Powerful jets, higher pressure than IP65 | High-pressure cleaning zones |
| IP69K | High-pressure, high-temperature washdown | Food processing and sterile rooms |
The rating covers the display panel only as tested — the full installed system has to match. Per NEMA’s guidance, the lowest-rated component sets the system rating: an IP65 conduit, fittings, and enclosure stays IP65 even if the monitor inside is IP67. One unsealed HDMI port or non-rated replacement cable can drop the whole setup below its label.
What The IP Code Leaves Out
An IP rating says nothing about image quality, corrosion, impact, chemical resistance, UV exposure, or long-term outdoor life. A monitor rated IP68 can still fail in salt spray or a chlorinated wash.
- IP codes do not convert directly to NEMA enclosure types, which add corrosion, icing, oil, and gasket-aging requirements.
- IP68 has no universal depth figure — ask for the tested depth, duration, and orientation in writing.
- Many IP-rated displays survive water contact but aren’t cleared to run while wet or submerged.
- Touchscreens may misbehave under water droplets, heavy gloves, or conductive cleaning fluid.
- Damaged seals, opened covers, or a repair can void the rating entirely.
If you’re shopping for a touch display that takes this abuse daily, our guide to the best waterproof touch screen monitors covers the models that hold up to real conditions.
How Do You Verify A Rating Before You Buy?
Ask the manufacturer for the exact model name, revision, and rated configuration in writing. Banner Engineering’s breakdown of IP ratings makes the same point: the code is only as good as the configuration it was tested in. Confirm these in the documentation:
- Whether the rating covers the whole enclosure or only the front face.
- Required connector caps, cable glands, mounting orientation, and torque values.
- Tested immersion depth and duration for IP68, plus whether operation while wet is allowed.
- Approved water type, pressure, temperature, and cleaning chemicals.
- Operating and storage temperature, humidity, and condensation limits.
- Whether touch input works with water droplets or gloves on the screen.
An IP-rated monitor protects its own enclosure — not the connected computer, power supply, or wall outlet, which need their own protection from the same water.
Common Questions
Is an IP68 monitor also safe for hose-down cleaning?
Usually not without a jet rating. IP68 covers immersion at a stated depth and duration; the jet test is a separate procedure. If your cleaning routine involves spraying, look for a combined mark such as IP65/IP68 or IP66/IP68 rather than a lone IP68 label.
Can I use a waterproof monitor outdoors year-round?
The IP code only confirms dust and water performance in the test. Sun exposure, freezing, condensation, and UV degradation fall outside IEC 60529 testing. Check the datasheet’s temperature and humidity ranges, and confirm the enclosure is rated for outdoor mounting if your installation is exposed.
What happens if I remove a cover or swap a cable?
Protection can drop below the rating, because IEC 60529 applies to the tested configuration. Replacing a gland, leaving a port uncapped, or opening the housing can void it. Use only manufacturer-listed parts, re-torque fittings to spec, and never apply power while connectors are wet.
Sources
- NEMA. “NEMA and IP Ratings” Explains IEC 60529 code structure and the lowest-rated-component principle.
- Banner Engineering. “IP Ratings” Details what each digit covers and how to read the enclosed configuration.
- Siemens. “IP vs. NEMA White Paper” Covers the IEC 60529 code and the scope of protection it does and does not cover.