Window AC side panels are accordion-style filler curtains that slide into the cabinet rails and expand to the window frame, sealing the gap, blocking outside air, and steadying the unit.
Those two plastic curtains do more than finish the look. Skip them, or seat them badly, and every dollar of cooled air leaks sideways past the cabinet while bugs and humid outdoor air slide in through the same gap. The panels don’t cool anything themselves — their whole job is enclosure, air sealing, and holding the unit steady in the opening.
Below is how the panels work, the install sequence manufacturers actually document, and the mistakes that turn a tight seal into a drafty one.
What Do Window AC Side Panels Actually Do?
Side panels close the space between the air conditioner cabinet and the window frame on the left and right sides. They do not touch the refrigeration system or make the unit colder — they enclose it.
GE describes the panels as parts that slide into the cabinet rails and extend to fill the window opening. In practice that means three jobs:
- Air sealing. The curtains stop conditioned air from escaping and stop hot outdoor air from sneaking in around the cabinet.
- Weather and pest blocking. Closed panels keep rain, insects, and debris out of the room-side gap.
- Stability. Extended curtains help center the unit and support the installation, though screws — not the panels alone — do the real securing.
The panels must never block the outdoor condenser louvers or the rear of the unit. Manufacturer instructions require clear space around the side louvers and back so heat can escape. Starve the condenser of airflow and the unit runs hot and inefficient.
How Do You Install Them? The Documented Sequence
Panels go on before the unit enters the window, and the exact hardware varies by model — so check your unit’s own instructions for the parts and pilot-hole locations.
- Confirm your window fits the model. Width and height ranges are model-specific; GE directs users to the unit’s installation instructions rather than a universal number.
- Add weather stripping to the sides of each curtain frame where it will meet the window opening.
- Free the panel’s open end by pulling back the panel center, then slide the molded section into the cabinet and push it downward.
- Seat the frame in the rails. Set the upper and lower frame ends securely in the cabinet’s top and bottom rails.
- Repeat on the other side and extend both panels out against the window frame.
- Center and secure the unit. Set the bottom mounting rail against the rear edge of the sill, close the window behind the top rail, extend the curtains, and drill roughly 1/8-inch pilot holes where the instructions call for them.
- Seal what’s left. ENERGY STAR criteria recommend weather stripping or gaskets at the unit-to-window, unit-to-sash, unit-to-sill or head, and fixed-to-movable-sash interfaces.
When it’s done right, both panels press firmly against the window frame with no visible daylight at the edges and the cabinet sits level and immobile when you nudge it. Lifting the unit usually takes two people — GE recommends a helper for positioning.
What Standards Apply To Side Curtains?
Version 5.0 keeps that R-1 minimum and adds a requirement for installation materials that minimize air leakage.
The specs also require the unit to ship with weather stripping and/or gasket materials, plus detailed installation documentation explaining where and how to seal. Two other details from manufacturer manuals matter in practice:
- Rear pitch.
- Clearance.
Which Mistakes Cause Leaks And Loose Installs?
Most panel problems trace back to seating and sealing, not to the panels themselves.
- Swapping left and right panels. The shapes are mirrored; they won’t seat correctly reversed.
- Half-seated frames. If the upper and lower frame ends aren’t fully in the rails, the curtain sags and gaps open at the corners.
- Unsealed gaps. Skipping the supplied weather stripping or sealant leaves air paths around the curtain frames.
- Assuming universal replacement panels fit. Rails, panel geometry, mounting holes, and window-width ranges are model-specific — match replacement parts to the exact model number.
- Loading the panels with weight. The unit must be mechanically secured with screws to sound wood, masonry, or metal; extended curtains alone are not support.
- Wrong slope or blocked louvers. Installing flat or blocking the condenser louvers undermines the whole installation.
If you’re replacing worn or missing panels, matching the model number first saves a return — a roundup of compatible options can shortcut the search, and our tested window AC side panel picks cover the common fit ranges.
One more compatibility note: side curtains are a window-unit feature. Through-the-wall models, casement-window units, portable ACs, and mini-splits use different mounting systems and may not accept standard accordion panels. ENERGY STAR’s room air conditioner installation guidance lays out the sealing points across the window interfaces.
Before removing panels for cleaning or storage, support the air conditioner’s weight and disconnect power — the panels aren’t load-bearing, and the unit can shift once they’re out.
Common Questions
Can I run the air conditioner without the side panels in place?
It will run, but you lose the air seal, insect protection, and part of the installation’s stability. The unit’s cooling system doesn’t depend on the curtains, so it won’t fail immediately. Manufacturer and ENERGY STAR guidance, though, treat tight-fitting, sealed side curtains as part of a proper installation.
Are accordion panels universal across brands?
No. Rail positions, panel geometry, mounting holes, and window-width ranges differ between models, even within one brand. Replacement panels should be matched to the exact model number on the unit’s rating plate. Measuring the old panel helps, but the model number is the reliable match.
Do the panels need extra insulation or sealant?
Most units ship with the required weather stripping. ENERGY STAR specifications require side curtains insulated to at least R-1, so added insulation usually isn’t necessary. Sealant or gaskets at the frame-to-window contacts, however, are recommended to close small remaining gaps and limit air leakage.
Sources
- GE Appliances. “Air Conditioner Side Panels” Describes how side panels slide into cabinet rails and extend to fill the window opening.
- ENERGY STAR. “Room Air Conditioner Installation FAQ” Lists the sealing points recommended across window interfaces.
- ENERGY STAR. “Version 4.1 Room Air Conditioners Specification” Sets the tight-fit, R-1 insulation, and weather-stripping requirements for side curtains.