Ducted Range Hood Sizing Guide: How Many CFM Do You Need?

The higher number isn’t upsell padding — it’s the difference between a hood that clears steam and one that lets grease settle on your cabinets. What follows is the arithmetic, the duct math that quietly steals your rated airflow, and the mistakes that make a correctly sized hood behave like an undersized one.

How Do You Calculate CFM For A Wall-Mounted Hood?

Multiply your cooking surface’s width in feet by 40 to 100 CFM per linear foot, then apply a 100-CFM minimum. A 30-inch range is 2.5 feet wide, so the band runs from 100 CFM to 250 CFM.

Which end of that band you pick depends on your cooking. Light-duty boiling and reheating sits comfortably at the low end. Searing, wok work, and frequent high-heat frying push you toward the top.

The hood should also be wider and deeper than the cooking surface where your layout allows it; greater coverage improves capture more reliably than another 50 CFM does.

Why Island Hoods And Commercial Ranges Break The Usual Rules

Island and peninsula hoods are sized from the combined length of their exposed sides — three or four — not just the appliance width, and capacity should rise when the hood sits more than 27 inches above the cooking surface.

The reasoning is straightforward. A wall hood gets a free assist from the wall behind it; an island hood pulls from all directions and loses that boundary. Sizing an island install with wall-hood arithmetic is one of the most common ways a new hood disappoints its owner.

Commercial-style equipment is a separate conversation entirely. ASHRAE 154 classifications run from under 200 CFM per linear foot for light-duty cooking to over 400 CFM per linear foot for extra-heavy-duty work. Residential rules do not transfer to wok ranges, broilers, or solid-fuel appliances.

Installation Type Sizing Basis Target Airflow
Wall-mounted, 30-inch range 40–100 CFM per linear foot 100–250 CFM
Wall-mounted, performance target ~100 CFM per linear foot 250 CFM
Island or peninsula Combined exposed sides Higher than wall equivalent
Hood over 27 inches high Standard basis plus a bump Increase above baseline
Light-duty commercial ASHRAE 154 Under 200 CFM per linear foot
Extra-heavy-duty commercial ASHRAE 154 Over 400 CFM per linear foot
ENERGY STAR certified hoods Efficiency and sound criteria Mostly 100–200 CFM

What Quietly Cuts Your Rated CFM?

Actual delivered airflow drops below the rated figure when the duct run exceeds 15 feet, narrows below 4 inches, contains multiple elbows, or uses corrugated duct. Those losses stack. A long, bendy, narrow run can gut the performance of a hood that looked generously sized on the box — and it will be louder while doing it.

Keep the run short and straight, follow the manufacturer’s specified duct diameter, and seal joints with mastic. Verify airflow at the outdoor termination when you measure an installed system, because rated fan capacity is not delivered airflow. If you’re shopping for a 30-inch model with these duct realities in mind, this tested roundup of 30-inch ducted range hoods shortlists units that hold up in real installations.

Sound deserves a look before you buy.

Makeup Air, Safety, And The Codes You Must Check

High exhaust rates create pressure imbalances, and tight, high-performance homes may need makeup air to replace what the hood pulls out. The DOE identifies makeup air as particularly important in those buildings.

A hood exhausting combustion byproducts has to discharge outdoors through ductwork. Recirculating and charcoal-filter configurations do not deliver the same source removal — the DOE sources cited here address vented kitchen exhaust specifically. Consult your locally adopted mechanical, fuel-gas, and residential codes before installation, and follow the hood and appliance manufacturer’s instructions wherever they are more restrictive than general guidance. Guidance based on ASHRAE Standard 62.2-2016 and Standard 154-2016 is summarized in the DOE ventilation systems measure guideline.

One more caution: maximum CFM is not automatically better. Oversized exhaust can tip a house into pressure trouble and drive a makeup-air requirement you didn’t budget for.

Common Questions

Is 250 CFM enough for a gas range?

For a standard 30-inch residential gas range under a wall hood, 250 CFM sits at the performance-oriented end of the recommended band and is generally sufficient. Higher-output burners and frequent high-heat cooking may justify more capacity, and commercial-style equipment follows entirely different sizing rules.

Does a longer duct run mean I need a bigger hood?

It can, but the better fix is usually rerouting the duct. Longer runs, extra elbows, and narrow or corrugated duct reduce delivered airflow, so a larger hood compensates for a problem that a shorter, smoother, correctly sized run would have avoided in the first place.

Should the hood be wider than my range?

Yes, when your layout allows it. A hood that extends beyond the cooking surface captures more rising grease and steam, and greater coverage improves capture efficiency more dependably than simply adding airflow to an undersized canopy.