A window well cover is measured across the top opening of the well, not the bottom or the window, because that upper lip is what the cover rests on.
Tape the bottom of a tapered well and the cover arrives too small. Tape the window instead of the opening and it arrives wrong entirely.
Which Parts Of The Well Do You Measure?
Record the well’s shape, width, and projection first, then add the extra figures your specific cover style calls for. Shape drives everything after it.
- Shape: rectangular, rounded, U-shaped, or atrium-style. Each one needs a different set of numbers.
- Width: measure side to side across the widest part of the opening. Take it at both the front and back where the well meets the house, then keep the larger figure.
- Projection: measure straight out from the foundation wall to the front or middle of the outer lip, depending on the cover design.
- Rounded wells: add the chord at the narrower front section and the radius, measured from the points where the curve begins on the front and side.
- Atrium covers: add window width and window height, the latter being how much window extends above the egress material.
Guardian’s measuring guide notes that width runs from the outside of the lip nearest the foundation to either the outside or the inside of the opposite lip, and projection ends at the front or middle of the front lip, depending on cover style. Confirm which edge reference yours uses before you write anything down.
A Window Well Cover Measurement Chart By Cover Style
Matching your well type to the required inputs keeps you from ordering with a missing dimension. Window Well Experts asks for inside width, projection, and outside width overall, plus lip-to-window-frame distances on both the left and right sides, and lip-to-ground distance for metal wells. They specify measuring to the nearest 1/8 inch.
| Well Or Cover Style | Dimensions To Record | Edge Reference |
|---|---|---|
| Rectangular, standard | Width, projection | Per cover style: inside or outside lip |
| Rounded or semicircular | Width at widest point, projection, chord, radius | Outside lip at foundation, front or middle of front lip |
| Atrium-style | Width, projection, window width, window height | Full perimeter of the egress material |
| Metal well | Inside width, outside width, projection, lip-to-ground, left and right lip-to-frame | Nearest 1/8 inch |
| Irregular or custom shape | Traced profile plus width and projection | Cardboard template over the opening |
| Undersized category | Under 4 ft in both width and projection | Guardian’s undersized class |
| Standard or oversized | Over 4 ft in both dimensions | Guardian’s larger cover classes |
How Much Overhang Should A Cover Have?
Overhang requirements differ by product, and the product’s own installation guide overrides any general rule. Guardian’s guidance calls for a rectangular or rounded cover to span the entire egress well and extend halfway through the egress material on all sides; its atrium covers extend to the edge of the egress material instead. A common working target is a 1-inch lip overhang around the perimeter. Read the guide that ships with your cover and let it settle the question.
Once the numbers are on paper, compare tested window well cover options against your dimensions rather than shopping by well size alone.
What Goes Wrong, And How Do You Avoid It?
Most bad fits trace back to measuring the wrong surface or the wrong spot. Tapered wells are narrower at the bottom, so a bottom measurement produces an undersized cover. The window itself is irrelevant to the cover’s footprint; covers are built around the well opening. A rounded well measured anywhere but its widest point comes out wrong, and using outside-edge figures on a cover that requires inside-edge ones creates a fit that simply won’t seat.
Measure twice and compare both readings. Large wells are easier and more accurate with a second person holding the tape level. Note whether the well is metal, concrete, plastic, wood, or brick, since manufacturer worksheets can ask for different inside and outside figures by material. Check whether the rear edge must slip into the foundation opening beneath the siding, a site detail worth confirming before ordering. For irregular shapes, lay cardboard over the well, press the edge to indent it, trace the profile, and send the template along with your width and projection. Then check for buckling, bending, or distorted clips, which signal a cover that isn’t sitting flat. Verify egress clearance and the cover’s release design as well, and check local building and fire requirements for your property.
Common Questions
Should The Tape Run Along The Inside Or Outside Of The Well?
It depends on the cover style. Guardian’s guidance allows width to be measured to either the outside or the inside of the opposite lip, and some manufacturer worksheets ask for inside width and outside width as separate figures. Check your cover’s requirements first, then take the matching measurement and record both if the form allows.
Can One Person Measure A Large Well Accurately?
It can be done, but a second person holding the tape level at the far end removes sag and keeps the reading true. Have someone hold the end, pull the tape taut, and read the number at eye level.
What Do I Do About An Oddly Shaped Well?
Make a template. Place cardboard over the opening, press down along the well lip to indent the edge, and trace that profile. Send the template with your width and projection figures, and a fabricator can produce a custom cover that follows the actual shape rather than forcing a rectangle onto it.
Sources
- Guardian Covers. “How to Measure Your Window Well for the Perfect Cover Fit.” Source for edge-reference rules, overhang guidance, and cover size categories.
- Window Well Experts. “Measuring Guide: Covers.” Source for required measurement fields by well type and material.
- Lowe’s. “How to Install a Window Well Cover.” Source for installation and fit checks.