A generator can run on propane only when the manufacturer sells an approved kit or LP fuel knob for that exact model — there is no universal conversion.
A gasoline-only unit fed through a drilled jet and a hardware-store hose is a fire waiting on a load. Propane metering is not a plumbing problem you solve at the fittings bin. Whether you can convert a generator to propane depends on what the maker documented for your serial number, and on Generac’s air-cooled line that documentation sometimes describes a knob, sometimes a jet, and sometimes a flat no.
One safety line before the steps: an unapproved modification can void the warranty and put raw fuel where it doesn’t belong. Everything below assumes LP vapor is a listed fuel for your model.
Which Generators Can Run On Propane?
A generator qualifies when its manual lists LP vapor as a supported fuel, either through a factory dual-fuel design or an approved conversion kit. Gasoline-only models have no approved path at all.
Generac’s published instructions sort supported units into three groups:
- Factory dual-fuel portables. The GP6700EDF, GP9500ETF, GP6500E DF and iQ3800 DF run on either fuel as built. You use the fuel selector and the startup order in the manual — no parts swap.
- Air-cooled standby units with a fuel knob. Most 10 kW through 26 kW models use an orange fuel-conversion knob at the mixer.
- Models that need a jet. The PowerPact 7.5 kW and certain other standby models require replacing the natural gas jet with a supplied propane jet.
Jet-based kits are model-specific, and the wrong jet leans the engine out. Our tested propane generator conversion kit comparisons show which kit matches which unit before you buy.
| Generac Model Or Family | Propane Setup | Detail Worth Knowing |
|---|---|---|
| 10 kW air-cooled standby | Orange conversion knob, below the mixer | |
| 14 kW–26 kW air-cooled standby | Same knob, mounted above the mixer | |
| PowerPact 7.5 kW | Supplied propane jet replaces the fuel jet | The manual controls the disassembly |
| Standby models needing a jet swap | NG jet out, propane jet in | Lid and rear panel come off first |
| GP6700EDF portable | Factory dual fuel, selector only | 6.0 kW rated on propane |
| iQ3800 DF portable | Factory dual fuel, selector only | 2,700 running watts on propane |
| Any gasoline-only generator | No approved conversion | Improvised fittings are not an option |
Propane costs you output. Generac rates the iQ3800 DF at 2,700 running watts on propane against 3,000 on gasoline — build your load list from the LP column, never the gasoline one.
Converting A Generator To Propane: Where The Steps Diverge
The outline is identical for every approved unit: verify support, fit the correct hardware, set the fuel path, test, then start unloaded. What changes between models is the hardware and where the fuel setting lives.
- Pull the manual for your exact model and serial number. Generac’s fuel conversion support instructions say it outright: no universal procedure exists, and the model manual controls.
- Fit only approved hardware. Depending on the unit that means a propane jet, a fuel selector, a mixer knob, a regulator, a hose, or a full kit. Unknown pressure ratings don’t belong in a fuel system.
- Shut down and isolate. Drop the electrical load, stop the engine, close the gasoline and propane valves, let hot parts cool, and work outdoors.
- Open the fuel path the way the manual shows. Jet-based standby units typically need the lid and rear panel off, the hose clamp released, and the fuel hose pulled from the inlet.
- Set the LP position. Swap the natural gas jet for the propane jet, or turn the orange knob fully toward the LP arrow — 180 degrees on supported standby models, until it seats into the mixer body. The knob sits below the mixer on 10 kW units and above it on 14 kW–26 kW units.
What To Check Before The First Start
Two settings decide whether the conversion works: fuel pressure and the controller’s fuel type. Both are model-specific, and neither can be guessed from a gasoline rating.
Pressure is not transferable. Use the figure printed for your unit, measured with a manometer, not a forum quote.
Controller programming applies to Next Generation Generac units, which need the fuel type entered in the Field Pro app during setup or through generator configuration settings. Generac directs owners to an authorized service dealer for that step.
Leak-test every joint before cranking it, using the manufacturer’s own method — soap solution, never a flame. If you smell propane, close the tank valve, clear the area, and call your supplier.
Start with the breaker off and nothing plugged in, let the engine stabilize in LP mode, then bring loads on one at a time. A correct conversion looks boring: steady output, no frost on the regulator, no fuel smell, no surging. If the engine hunts or frosts up, shut it down and have the fuel pressure, jet, regulator, and installation checked before it runs again.
Common Questions
Do You Need A Licensed Technician For The Conversion?
On a portable dual-fuel model, no — the fuel selector and startup order are owner-level tasks. On a standby generator tied into a house panel, Generac points owners to an authorized service dealer for controller programming, and propane piping plus leak checks usually fall to a licensed propane technician. The gas work and the electrical work are separate jobs in most states.
How Much Power Does A Generator Lose On Propane?
Propane delivers less output than gasoline from the same engine. Generac lists the iQ3800 DF at 2,700 running watts on propane versus 3,000 on gasoline, and rates the GP6700EDF at 6.0 kW on propane. Build your load list from the propane figure in your manual and keep a margin for motor-starting loads like a fridge or well pump.
What Happens If You Run Propane Through A Gasoline-Only Carburetor?
The engine gets the wrong fuel-air mix, because a gasoline jet is sized for liquid fuel while LP vapor travels through the system as a gas. Expect hard starting, surging, or an engine that stalls under load. A modified gasoline-only unit also has no manufacturer-approved fuel path, which puts the warranty and the fuel system’s integrity on the line.