A recessed outlet box is chosen by location first: wall boxes hide plugs behind drywall, floor boxes serve wood framing, and poke-thru devices handle concrete slabs. Getting this wrong is expensive — a wall receptacle dropped into concrete won’t pass inspection, and a commercial poke-thru in a wood-framed living room wastes money on an unneeded fire-rated assembly. Location decides core hole size, cut depth, device capacity, and the required listing.
Which Recessed Box Fits Your Location?
Wall-mounted recessed receptacles serve standard wall depth, wood-floor boxes serve framed residential floors, and poke-thru or concrete floor boxes serve poured slabs in commercial and retrofit work. Each carries its own depth requirement, knockout pattern, and capacity ceiling.
The Legrand R885TRWCC6 covers the wall case: a 15 A, 125 V indoor tamper-resistant duplex receptacle that keeps appliance plugs recessed behind the finished wall. Legrand identifies it as compliant with NEC tamper-resistant-receptacle requirements.
It has 2-inch and 3/4-inch knockouts with through-floor cable entry and is cULus-listed for nonmetallic outlet boxes under NEC Article 314.27(C).
Concrete and commercial floors move to poke-thru territory. Legrand’s 4-inch poke-thru devices provide recessed power, communications, and A/V service; the 4AT family is listed for US and Canadian applications. For living rooms or media walls, this roundup of the best recessed wall outlet options for TV setups shows tested picks that hide cords behind the screen.
Specs That Decide The Box: A Field Comparison
The three families differ most in core hole size, capacity, and fire rating. Legrand publishes these figures directly — match your cutout and conductor count against them before ordering.
| Box Type | Key Specs | Best For |
|---|---|---|
| Wall recessed receptacle (R885TRWCC6) | 15 A, 125 V; tamper-resistant duplex; standard wall depth | Hiding plugs behind a wall |
| Wood-floor recessed box | 3-7/8 in deep; 5 in min floor depth; 2 in and 3/4 in knockouts | Wood-framed residential floors |
| 4AT poke-thru (prewired all-power) | 4 in core hole; 24.5 in³; 2-hour fire rating; 3/4 in and 1-1/2 in knockouts | Commercial concrete, power only |
| 4AT dual-service poke-thru | Two outlets; 4 in core hole; 2-hour fire rating; prewired | Power plus data at one desk |
| 4AT four-outlet poke-thru | 4 outlets; 10 knockouts; 18.562 in × 5.5 in; 2-hour fire rating | Conference and shared work areas |
| RFB2E two-compartment concrete box | 16 knockouts (3/4 in to 1-1/4 in); takes 2 in hub model 2HUB | Bare concrete, carpet, tile, terrazzo |
| 4AT unwired (black) | UPC 786564090564; 5.75 lb; UL Fire Classified, cULus, NEC compliant | Contractor-finished field wiring |
Electrical And Installation Checks Before You Cut
Confirm amperage, voltage, branch-circuit rating, grounding, wiring method, and tamper resistance before any cutout opens. One trap: Legrand states its 15 A receptacles have 20 A feed-through capability, but a 15 A receptacle cannot be the only device on a 20 A branch circuit. Feed-through means the circuit continues past it to other devices — not that the receptacle is rated for 20 A. Check local amendments too, since they vary by jurisdiction.
- Match the box to floor construction: wood framing, bare concrete, carpet, tile, or terrazzo.
- Verify knockout sizes line up with your conduit and hub, including the RFB2E’s 2-inch trade-size hub.
- Confirm the fire rating where the assembly penetrates a rated floor — the 4AT poke-thru is 2-hour rated.
- Count services: single, dual, or four outlets depending on devices sharing the spot.
How To Pick The Box Without Overbuying
Start with location, lock the rating, then size for devices. That order prevents the two most common errors: buying commercial hardware for a bedroom wall and buying a shallow box that won’t clear the plug.
- Name the surface — drywall, wood floor, or concrete slab.
- Set the electrical rating against the circuit; confirm the 15 A versus 20 A branch-circuit logic.
- Measure clearance and depth against published box dimensions before cutting.
- Pick capacity: how many outlets and services does the spot truly need?
- Match the listing and fire rating to the building type.
You’ll know the pick is right when the cutout matches the published core hole or box dimension on the first try, the cover sits flush, and the inspector’s checklist clears without a re-cut.
Common Questions
Can A 15 A Receptacle Go On A 20 A Circuit?
Yes, with a condition. Legrand states its 15 A receptacles have 20 A feed-through capability, but the 15 A receptacle cannot be the only device on a 20 A branch circuit. Feed-through passes the circuit onward to additional devices. Verify the circuit and local amendments before installing.
What Is A Poke-Thru Device Used For?
A poke-thru device delivers recessed power, communications, and A/V connections through a concrete floor, typically in commercial spaces. Legrand’s 4-inch models are listed for US and Canadian applications, fit a 4-inch core hole, and carry a 2-hour fire rating on rated assemblies.
How Deep Does A Wood-Floor Recessed Box Need To Be?
The box itself measures 3-7/8 inches deep, and the manufacturer specifies a minimum floor depth of 5 inches for that single-gang unit. Measure your floor assembly before cutting. Through-floor cable entry and 2-inch and 3/4-inch knockouts handle the wiring.