How to Test a Furnace Ignitor and Limit Switch Before Replacing | Readings That Mislead

A healthy hot-surface ignitor reads about 40–75 ohms; a cool limit switch should show continuity, and a bad reading still means checking airflow.

A furnace that clicks and never lights sends homeowners straight for a new ignitor, yet ten minutes with a multimeter can separate a dead part from a starving burner. The order that works for testing a furnace ignitor and limit switch before replacing either one runs from the breaker, to the gas valve, to the model-specific wiring diagram. Below are the resistance windows, the continuity check, and the airflow faults that fool the meter.

Shut Off The Breaker And Gas Valve Before Any Meter Work

Kill power at the furnace disconnect or breaker, close the gas valve, and let the unit cool before a panel comes off. A hot-surface ignitor holds enough heat to burn skin, and a live circuit will wreck a meter set to resistance.

Pull the furnace’s own wiring diagram and service manual first, since wire colors and terminal layouts change between models. Gas-side work stops at the shutoff valve: opening a manifold, adjusting burners, or chasing a gas valve is licensed-technician territory. This procedure covers residential gas furnaces in the US, not electric furnaces, boilers, or commercial rooftop equipment.

If you smell gas, leave the house and call the utility from outside. If a carbon monoxide alarm sounds, get everyone into fresh air and call emergency services.

Testing A Furnace Ignitor And Limit Switch: What The Meter Should Show

A hot-surface ignitor on Rheem’s specification should measure 40 to 75 ohms through the burner-tube receptacle, and a limit switch at room temperature should read continuity, close to zero ohms.

The ignitor test runs in four steps:

  1. Power off at the breaker, gas valve closed, ignitor cool to the touch.
  2. Unplug the burner plug and the AMP plug from the burner-tube receptacle.
  3. Set the meter to resistance and probe the ignitor circuit through that receptacle.
  4. A reading inside 40 to 75 ohms passes; infinite or zero ohms means a failed ignitor.

ICM Controls widens the window to 40 to 200 ohms and treats a low reading as probable replacement. When the two numbers disagree, the furnace manual and the ignitor’s own part sheet win, because a generic figure can clear a part that will never glow.

Limit switch: power off, panel off, spade connectors pulled after a photo of the wiring, meter on ohms or continuity, probes on both terminals. A cold switch should show continuity, because it only opens when heat reaches its trip point. An OL or infinite reading on a cool furnace means an open circuit worth diagnosing, not an instant swap.

Bryant’s limit switch notes and Rheem’s gas furnace service manual both use the same continuity-first sequence, and both assume the meter is isolated from any live circuit.

Part Tested Meter Check What The Reading Means
Hot-surface ignitor Ohms through the burner-tube receptacle 40–75 ohms passes; zero or infinite fails
Hot-surface ignitor, field guide Ohms across the ignitor itself 40–200 ohms runs; a low reading usually fails
Ignition module VAC at the 24-V terminal to common 24 VAC during a heat call; nothing means a control fault
Limit switch, cool Continuity across both terminals Near zero is normal; OL means an open circuit
Limit switch, live Voltmeter across the terminals 120 V ±10% means the contacts have failed
Limit switch, tripping often Read against its trip temperature Opens early: check filter, blower, ducts, venting
Any part, warm cabinet No test Let it cool first; warm readings mislead

Why Does A Furnace Still Fail When The Meter Reads Fine?

Resistance proves a filament survived and says nothing about cracked ceramic, a loose ground, a control board that never sends voltage, or a switch tripping because the furnace is suffocating.

Check the ignition module next. With the thermostat calling for heat, the module should see 24 VAC at its 24-V terminal relative to common. That is a live-voltage test, so it belongs to someone comfortable working inside an energized control compartment with the diagram open.

When a limit switch keeps opening, the switch is usually the messenger. Dirty filters, clogged ducts, restricted returns, a failing blower, a plugged flue, blocked venting, over-fired gas input, and heat exchanger trouble all push the cabinet past its trip temperature. Change the filter, confirm the blower spins, and look at the venting before a switch goes in the cart.

Never jumper a limit switch to stop the cycling. The switch is the last safety device between a restricted furnace and a fire or a carbon monoxide problem. Match a replacement by manufacturer, model, serial number, electrical rating, switch temperature, and terminal layout; tested Trane ignitor and limit switch matches make that cross-reference easier than guessing from a photo.

The sequence that saves the most money: breaker off, gas off, cool down, ohm the ignitor against the manual, continuity-test the limit switch cold, then check the filter, blower, and venting before any part gets ordered.

Common Questions

How Many Ohms Should A Hot-Surface Ignitor Read?

Model documentation sets the number, and Rheem’s spec for its burner-tube circuits is 40 to 75 ohms. A wider 40 to 200 ohm window shows up in some field guides. Treat anything infinite or zero as a dead ignitor, and check the manual before trusting a reading that barely scrapes the bottom of the range.

Can A Bad Limit Switch Cause Short Cycling?

Yes. A switch that opens too early cuts the burner before the blower satisfies the thermostat, so the furnace restarts, overheats, and shuts down again. Rule out a dirty filter, a slow blower, or blocked venting before replacing it, since those raise cabinet temperature and make a healthy switch open on schedule.

Is Replacing An Ignitor A DIY Job?

For an experienced adult with a properly rated multimeter, an ignitor swap is a common homeowner repair: power off, gas off, unplug the burner lead, unscrew the bracket, fit an exact-match part. Gas valves, burners, and manifold work are not DIY territory, and a cracked ignitor with no obvious cause deserves a technician’s eyes.

Sources

Scroll to Top